Revolutionizing Radiation Detection Safety with M3D

It’s Time for Change in Healthcare Radiation Safety
Walk into any major medical facility in the world and chances are that you’ll quickly come across a Radiology or Nuclear Medicine department full of modern medical imagers. From mammograms to CT and PET scanners, it’s no secret that radiation plays a pivotal role in everyday modern imaging and healthcare. Radiation is critical in modern medicine, from diagnosing injuries and diseases to treating cancer.
However, the use of radiation comes with inherent risks – including the potential for harm to patients, healthcare workers, and the general public through the leakage and scatter of X-rays through walls or from contamination of hospital facilities with radioactive materials. This risk is especially true given the rise in the number and complexity of imaging and therapy procedures involving X-rays and radiopharmaceuticals during the last decade. Ensuring the safety and well-being of everyone within healthcare environments requires vigilant monitoring and management of radiation exposure.
Today, all medical systems are aware of the occupational hazards of radiation and have radiation safety and mitigation procedures in place. Yet, even though the complexity of radiation imaging and treatment procedures has increased dramatically, the tools available to radiation safety personnel have not substantially improved in many decades. But that is changing.
The Importance of Radiation in Healthcare
Radiation has become an indispensable tool in healthcare, used across various applications from diagnostic imaging and treatments to sterilizing medical equipment. Diagnostic techniques such as X-rays, CT scans, and nuclear imaging rely on radiation to provide detailed images of the body's internal structures and immune and metabolic processes.
These techniques enable accurate diagnosis of conditions ranging from bone fractures and heart disease to tumors. In therapeutic contexts, radiation plays a crucial role in cancer treatment, targeting malignant cells with high-precision doses to maximize damage to the tumors while minimizing collateral damage to surrounding healthy tissue.
Beyond diagnostics and treatment, radiation spans a broad range of healthcare activities, from sterilization of surgical equipment to research into the underlying cellular and chemical processes in our bodies.
Of course, the benefits of radiation come with managing its risks. If not adequately controlled, radiation exposure can lead to facility contamination and potential harm to patients, healthcare workers, and the general public. This makes detecting and managing radiation contamination in healthcare settings critically important. Effective radiation safety practices are essential to protect patients and healthcare professionals from unnecessary exposure, aligning with the overarching radiation safety principle of A.L.A.R.A (As Low As Reasonably Achievable), which has been developed and adopted by the medical and radiation safety communities.
The Evolution of Radiation Safety and Detection
Since Wilhelm Conrad Röntgen's groundbreaking discovery of X-rays in 1895, radiation in medicine has undergone a profound transformation, evolving from a scientific curiosity into a cornerstone of modern diagnostic and therapeutic practices. This journey has not only expanded our capabilities to diagnose and treat diseases with remarkable precision but has also introduced complex challenges in ensuring radiation safety and managing radiation contamination risks.
In the early days following the discovery of X-rays, the medical community quickly embraced this novel technology, marveling at its ability to provide a non-invasive glimpse inside the human body. However, the lack of understanding regarding radiation's potentially harmful effects led to unregulated use, often resulting in significant unintended (and intended) health issues for both patients and practitioners. It wasn't long before the consequences of radiation exposure — ranging from skin burns and eye irritation to more severe radiation-induced conditions — prompted the need for safety measures.
With the rapidly growing use of X-rays for medical purposes and the subsequent reports of X-ray-induced injuries, the Röntgen Society was formed in 1897 to address safety concerns. Within its first year, they set up a committee to "report on the alleged injurious effects of x-rays." Through this commission, several notable events occurred:
- In what was likely the first expression of the three pillars of radiation safety – Time, Distance, and Shielding – early pioneer Wolfram Conrad Fuchs (1896) recommended keeping X-ray exposures as short as possible, keeping the X-ray tube at least 30 cm away from the body, and rubbing bare skin with petroleum jelly before exposure.
- At the American Röntgen Ray Society meeting in 1907, Rome Vernon Wagner reported keeping a small photographic plate in his pocket that he developed every night to determine if he had been exposed that day. This report was likely the first description of a personal dosimeter for radiation protection.
- In 1911, Marie Curie weighed a sample of pure radium and measured its activity. The records were placed in the International Bureau of Weights and Measures in Paris to establish the standard unit of radioactivity (1 Curie). In the following decade, scientists and political officials established committees on radiation safety and standards in many countries across Europe and North America.
- The German Röntgen Society published the first safety recommendations for X-ray exposure in 1913, quickly followed by societies in many countries. These recommendations led to the standard unit of exposure (the Röntgen) and the establishment of international organizations like the ICRU and ICRP that still help guide and set the development of radiation protection standards today.
Establishing these radiation safety standards and practices marked a significant milestone in the history of medical radiation use. Early radiation detection methods included photographic plates and open-air condenser ion chambers like the one Marie Curie used in her initial radium experiments. However, both methods have very low sensitivity to x-rays and gamma rays and produce highly variable readings from one experiment to the next.
By the mid-20th century, radiation scientists were rapidly developing methods to measure radiation exposure accurately and reproducibly.
Geiger-Müller Counter (1920s): Based on initial work with alpha particles by Hans Geiger in 1908, the expansion of the technology to detect other forms of ionizing radiation by Geiger and Walther Müller set the stage for devices still in use today. When radiation passes through a vacuum-sealed tube, it ionizes gas, leading to an electrical pulse. They are widely used for basic radiation level monitoring, including surface contamination and personal exposure assessment in healthcare facilities.

Pressurised Ionization Chamber (1930s): Developed in 1930s and commercialized by Victoreen Corporation in the 1940s, these devices draw from the same principles used by Marie Curie in her studies of radium in the 1890s. The ionization of atoms in the air and the collection of liberated charges determine the activity levels of a radioactive source. These detectors represented a portable and more reliable method to measure activity.

Scintillation Detectors (1940s): The practical scintillation detector was developed in the 1940s by Sir Samuel Crowe Curran and William R. Baker during their work for the Manhattan Project. Scintillators use materials that fluoresce when struck by ionizing radiation. The emitted light is then converted into an electrical signal by a photomultiplier tube, a novel invention at the time. Scintillators have been used for sensitive detection of low-level radiation and in applications requiring nuclide identification, such as nuclear medicine.

Semiconductor Detectors (1960s): Semiconductor materials (like silicon, germanium, or cadmium telluride) create electron-hole pairs when ionizing radiation passes through, which sensors detect as an electrical signal. Semiconductor detectors are used for precise radiation measurements and spectroscopy, including radiopharmaceutical handling and contamination monitoring. While a massive leap in technology at the time – one that would eventually lead to modern SPECT radiation imaging – silicon detectors struggle to detect high-energy radiation. In addition, germanium detectors require cooling to liquid nitrogen temperatures, and CdTe detectors suffer from polarization.

Personal Dosimeters (1970s - today): Personal dosimeters are pocket-sized devices or cards used to monitor occupational radiation exposure. Replacing film x-ray badges in the 1970s, dosimeter devices function via thermoluminescence, optically stimulated luminescence, or semiconductor technology. They are worn by healthcare professionals to monitor cumulative radiation exposure, ensuring individual safety limits are not exceeded.
Cadmium Zinc Telluride (CZT) Detectors (2000s - today): The recent advancement of CZT crystal fabrication techniques has launched a new era of semiconductor-based detectors. CZT is a semiconductor material that directly converts radiation into an electrical signal without cooling to cryogenic temperatures. It is used today in nuclear medicine for high-resolution SPECT imaging. It can even be used in radiation safety, detecting and imaging contamination with high accuracy and specificity.

While our awareness of radiation safety needs has come a long way since the 1920’s and 40’s, the technology to act on our collective caution has not. Despite the incredible advancements healthcare has seen in the radiation-based diagnostics and nuclear medicine space, post-procedure cleanup teams still rely on ion chambers and Geiger counter detectors based on science and technology over 100 years old. It’s time for a revolution in radiation detection technology.
M3D Imaging’s Breakthrough Technology
M3D Imaging's cutting-edge application of Cadmium Zinc Telluride (CZT) technology marks a significant leap in radiation contamination detection within healthcare settings. Featuring high sensitivity and the ability to produce 3D heatmap radiation images, M3D's CZT-based detectors enable real-time radiation monitoring. The system is capable of identifying even trace levels of surface contamination. This innovation is made possible by novel CZT growing techniques that marry with a proprietary ASIC chip interface to produce unrivaled imaging resolution currently used as the basis of military nuclear monitoring technology.
The impact of radiation contamination in healthcare settings is multifaceted. For patients, it can mean unintended exposure that may increase the risk of radiation-induced conditions. For healthcare workers, chronic exposure, even at low levels, can elevate the risk of health issues over time. Furthermore, unexpected contamination can lead to costly clean-up efforts, disrupt healthcare services, and damage the reputation of medical facilities. Effective detection and management of radiation contamination are thus paramount for safety, compliance, and maintaining trust in healthcare systems.
Join the Revolution in Radiation Safety with M3D
M3D’s radiation safety monitoring camera offers precise, immediate insights into radiation levels and surface contamination. With an intuitive interface and seamless integration into existing healthcare practices, concern over missed post-op contamination will be a thing of the past.
Join M3D in advancing healthcare radiation safety. With M3D's innovative technology, you can focus on what truly matters—delivering exceptional care. Contact us today to see how easily M3D's radiation detection safety camera can be integrated into your healthcare practice and take the first step towards setting a new standard in radiation safety.
More from the blog

3D CZT: The Future of Radiation Detection
Modern radiation detection plays a crucial role in healthcare, safeguarding patients and professionals by monitoring and managing exposure levels. arrived in fits and spurts – reactionary inventions to major events li

Radiation Survey Meters: A Comprehensive Guide
Learn about the evolution and types of radiation survey meters for ensuring safety in healthcare.

M3D Receives NSF SBIR Phase I Grant to Advance Gamma Camera Design
The team at M3D is thrilled to announce a $275,000 SBIR Phase I grant from the National Science Foundation (NSF) to support our innovative research on gamma camera technology. This award, coupled with $25,000 in matching